SYSTEM OPERATION
6-52
System 2 Installation / Programming Manual
Door Functions
Time Cancel
When the door is closed before the allotted time, any remaining programmed door release time will be
canceled. This prevents unauthorized "follow throughs".
Door Ajar
After a valid entry or exit, if the door is held open five seconds beyond the programmed door release time, an
event is generated and a “Door Ajar” message will appear on the LCD: Door Ajar 1 hh:mm mm/dd.
(This example shows the Door Ajar on port one). When the door closes, a “Door Closed” event is generated
and a message appears on the LCD: Door Closed 1 hh:mm mm/dd.
Forced Entry
If the door is opened without first using a valid code or by using an RTE button, an event is generated and a
“Forced Entry” message will appear on the LCD: (This example shows the event on port one) Forced
Entry 1 hh:mm mm/dd.
Request-To-Exit
When the RTE button is pushed, the main relay will close for the programmed door release time, an event is
generated and a “Request To Exit” message will appear on the LCD: (This example shows a RTE on port 2)
Request To Exit 2 hh:mm mm/dd.
Status of AC Power
If AC power is lost and the System has a standby battery connected, the following message will be displayed
on the LCD: AC Off hh:mm mm/dd. When AC power is restored AC On hh:mm mm/dd will be
displayed on the LCD.
Reset
System 2 has a "watchdog" circuit that resets automatically on power up or when electrical noise interrupts the
microprocessor. A manual reset button can also create a reset condition. When a reset occurs, a “System
Reset” event will be created and two “Module Reset” messages will also be displayed on the LCD. Other
messages may also appear on the LCD: “Forced Entry” and “Zone On” events will be created if connections
to these terminals are not completed and their inputs are open.
System Reset hh:mm mm/dd
AC On hh:mm mm/dd
Module Reset 1 hh:mm mm/dd
Module Reset 2 hh:mm mm/dd