PC/VDT PROGRAMMING - AUXILIARY OUTPUTS
9-189
System 2 Installation / Programming Manual
Trigger Event
As we mentioned above, an output can be triggered by a System event. Example: If you are
programming Auxiliary Relay #1, and want it to activate when an invalid code is used at one of
the readers, select 11 - Inv Code. You can now wire this Relay to a light, bell, whistle, etc. and
each time there is an invalid code Auxiliary Relay #1 will activate.
If you do not wish these outputs to activate from any System event, press 0.
At this point, you may select which event, if any, will trigger this output.
The VDT will display the instructions:
1=System Reset
2 = AC Off
3 = AC On
4 = Memory Clear
5 = Relay Override
6 = Door Ajar
7 = Door Closed
8 = Forced Entry
9 = Valid User
10= Inv
11 = Inv Code
12 = PIN Error
13 = Sched Error
14 = Request To Exit
15 = Unknown Event
16 = AP Error
17 = Door Perm
18 = Daylight Savings
19 = Powerup
20 = Zone On
21 = Zone Off
Enter (0 for None) [_0]
At the Event (0 for None) [_ 0] prompt, enter your selection followed by ENTER.