LCD PROGRAMMING - BATCH ENROLL CARDS
8-125
System 2 Installation / Programming Manual
Use 4 Digits
Enter Seed # [ _ _ _ _ ]
Assign These Output(s) þþþþ
Outputs [ - - - - ]
Seed Number
If you do not intend to use Keypads on your system, exit this option and return to Option #5 -
Port Configuration and set all your ports to Card Only.
What is a Seed Number? Here’s an example: You select a seed number of 1000, Batch Enroll
200 users, and use the System for months or years. One day, someone accidentally erases
memory. Now everyone’s codes are erased. No problem! When Batch Enrolling Users again,
simply select Seed Number 1000 again, and the System will assign the identical codes it did
previously, saving you time of issuing new numbers, and users the aggravation of memorizing a
new code number. Of course, be sure to write down the seed number and store it in a safe place
for future use.
The Seed Number must be four digits. Again, you may not use Leading Zero’s.
Note: This prompt will only appear if any of your ports are selected as Card or Keypad
or Card and Keypad. Remember, the system default is for Keypad Only. If you have the
network option active and any of the up to sixteen ports have not been changed to Card Only (if
this is what you desire), you will have to enter a seed number here.
The LCD may scroll the instructions:
Enter your four digit seed number and press #.
Additional Outputs
When a valid card is entered, the door relay for that Port may be activated. In addition to this
activation, you might want other outputs to be activated to sound an alarm, trip a dialer, or send
some other signal. There are four such outputs from which to choose. The Program Aux
Outputs section of this manual details the physical properties of the outputs. Any, all, or none of
these outputs may be activated by a user, if the Second Door is activated.
Refer to Option #13 to purchase this option.
The LCD will scroll the instructions:
Scrolling Options: to User ID
1=Aux Relay 1
2=Aux Relay 2
3=Voltage Output 1
4=Voltage Output 2
0=None
At the Outputs [ - - - - ] prompt, enter the desired output(s), if any, then press #.
Example: If you select Outputs 1 and 3, each time this group enters their code the door will
open and Aux Relay 1 and Voltage Output 1 will activate... provided you have installed a two-
door System 2 (2016).