Myalarm V-LCD1 Manual de instrucciones Pagina 284

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 336
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 283
TERMINAL DESCRIPTIONS
C-278
System 2 Installation / Programming Manual
Terminal #22 - (-) Common negative
This is the System 2's common negative for Readers, Keypads, RTE buttons, Magnetic Contacts
and LEDS.
Terminal #23 - DATA 0 and Magnetic Stripe Data
This terminal serves as the data 0 connection for Wiegand and Proximity readers and as the data
input for Magnetic Stripe and Bar Code readers.
Terminal #24 - DATA 1 and Magnetic Stripe Clock
This terminal serves as the data 1 connection for Wiegand and Proximity readers and as the
clock input for Magnetic Stripe and Bar Code readers.
Terminal #25 - Data Chip DATA
This is the Data line for the Data Chip reader. No other readers use this terminal.
Terminal #26 - Door Ajar, Forced Entry and Time Cancel Input
This input serves three functions at the same time and uses a closed circuit switch contact
mounted to the door. This switch is a typical alarm type magnetic switch and must be closed
when the door is closed for proper operation. Use this terminal in conjunction with terminal #22
common negative.
Terminal #27 - Request To Exit Input
Terminal #27 is the Request-to-Exit (RTE) input line. Whenever Terminal #27 is shorted to
Terminal #22 common (-), the main relay will activate as if a valid code/Card was entered. RTE
contacts must be open circuit. Please Note: RTE connections should be made away from the
Keypad or Card Reader for security reasons.
Terminal #28 - Reader / Keypad (+)5VDC
This terminal is rated at 125 mA maximum. It is used to supply power to Wiegand, Magnetic
Stripe and Bar Code Card Readers.
Terminal #29 - Reader / Keypad (+)12VDC
This terminal is rated at 250 mA maximum. It is used to supply power to Keypads, LED’s and
Proximity readers. No power is available to power door strikes or Mag-Locks.
Terminal #30 Green LED (-) Driver
This is a negative output for Light Emitting Diodes (LED). It is rated at 50 mA Maximum.
When the main relay is activated the LED on the Keypad or Card Reader will light to show that a
valid code/Card was entered.
Terminal #31 Red LED (-) Driver
This is a negative output for Light Emitting Diodes (LED). It is rated at 50 mA Maximum.
Normally this output is on, lighting the LED. The Red LED goes off when the main relay is
activated.
Terminals #32 through #34 - Door Relay
These contacts are rated at 5 AMPS 30 volts DC. They can be used to switch power to a lock or
gate, or arm / disarm an alarm system. Terminal #32 is Normally Open, #33 is Common, and #34
is Normally Closed.