OPTIONAL EQUIPMENT
4-17
System 2 Installation / Programming Manual
CHAPTER 4
OPTIONAL EQUIPMENT
Programming Wand
To assist you while entering Data Chips we highly recommend you purchase a programming wand (p/n 2018).
This wand plugs into Socket 6 (SCKT6) in the upper right hand side of the circuit board. If you do not wish to
purchase this wand you can program Data Chips using the touch point (TP1) located to the right of SCKT6.
Line Extender Module
The Corby Line Extender Module (LEM - p/n 4056) improves performance and extends the distance of a
Wiegand, Bar-code or Mag-stripe Card Reader an additional 500 ft. from the System 2.
The best place to install the LEM is at the midway point of the cable between the reader and the System 2.
Multiple LEMs can be connected at 500 ft. intervals to increase the reader distance.
When connecting more than one LEM to a single reader, wire size must increase to compensate for the
voltage drop which occurs with long wire runs. Wiegand readers require 4.75 - 5.25 VDC. Proximity readers
require 12-14 VDC. Mag-stripe and bar-code readers are particularly sensitive to low voltage created by long
wire runs and you must compensate for the extra voltage drop by running heavier wire or doubling up on
conductors.
The LEM is not waterproof and must be mounted in a dry secure area. Avoid placing the LEM outdoors. If
mounting an LEM outdoors is absolutely necessary, a sealed weatherproof box or enclosure must be used.
Door Locks
Door Strikes and Magnetic Locks must be Direct Current (DC) type, can be 12V or 24V and need their own
power supply. AC strikes are not recommended because they generate electrical noise and Electro-magnetic
interference (EMI) that is difficult to eliminate. We recommend magnetic locks (Mag-Locks) because they
almost never wear out, and rarely need service. External power supplies are required for all door lock
devices. A two conductor 16 or 18 gauge wire is suggested for door lock wire. It is OK to use shielded wire
but it is not required. Install a diode across the coil of the DC door lock (at the lock) to prevent noise
spikes.
Your door lock will require the use of an external power supply.
Be sure there is a door which can be accessed in case of an emergency. If all doors are secured with a
electric door lock and the power and backup battery fail, you may find yourself locked in/out of the
building.