3440-0241 Rev G
6
58 C PGM 2 Cutoff
(2 Digit Entry)
This output will stay energized for the amount of time
programmed in this memory location after an alarm circuit trips
and it has been programmed to energize the PGM 2 output,
Value 00 - 99 minutes, Default: 0 minutes.
NOTE
: A value of 00 will keep PGM 1 and PGM 2 output
energized until a valid PIN is entered.
Memory Location 59 & 59B
PGM OUTPUT OPTION
59 PGM 1 Output Option
(2 Digit Entry) PGM 1 Output can
be programmed to be used as
one
of the following functions:
The current available for this output is 20mA.
00 - Alarm Output
- This option must be enabled when
used as a Zone Alarm Output. Output time follows value in
location 58 B.
01 - System Status
- If this option is selected PGM 1
output will be present when all zones are secured When
the system has been armed this output will not be present.
02 - Ground Start
- Can be used for a phone system that
requires a ground to be produced on either tip or ring to
bring up a dial tone. This output will be present for 2
seconds.
NOTE:
Additional hardware is required, see page 14 for
wiring diagram.
03 - Fail to Communicate
- Can be used when the dialing
attempts have been exhausted that is programmed in
memory location 53 B. After the last dial attempt, this
output will be present.
04 - Follow Entry - Exit Delay
- When this option is
selected, this output will be present for the amount of time
programmed in entry exit delay times
(see memory location 57).
05 - PGM 1 Output with Utility PIN
- When this option is
selected, you must also program the utility PIN in the user
program in memory location 2. When the utility PIN is
activated this output will be present for five seconds.
06 - Long Range Radio Output
- When this option is
selected, the audio data signal for
Varitech
(only) long
range radio transmission will be present at this output.
07 - Partition One Status
- This option allows the PGM-1
output to be utilized as an armed status indicator for
partition one.
Value 00-99Default: 99 (Disabled
)
NOTE:
08-99 Disables this Option
59 A PGM 2 Output Option
(2 Digit Entry) PGM 2 Output
can be programmed to be used as
one
of the following
functions: The current available for this output is 20mA.
00 - Alarm Output
- Is used in conjunction with Zone
Output. Output value follows time in location 58 B.
01 - System Armed Status
- When this option is selected,
this output will be present when the exit time has expired
and will remain until the system is disarmed.
02 - Not Used
- for future use.
03 - Fail to Communicate
- Can be used when the dialing
attempts have been exhausted that is programmed in
memory location 53 B. After the last dial attempt, this
output will be present until communication is restored.
04 - Follow Entry - Exit Delay
- When this option is
selected, this output will be present for the amount of time
programmed in entry exit delay times
(see memory location 57).
05 - PGM 2 Output with Utility PIN
- When this option is
selected you must also program the utility PIN in the user
program in memory location 2. When the utility PIN is
activated this output will be present for five seconds.
06 - Radio Key Output for Long Range Radio
.- When
this option is selected , the Varitech radio key will be
produced.
07 - Ring Back
- When this option is selected this output
will be activated for two seconds after the open and close
report has been acknowledged. (See memory location 60)
08 - Partition Two Status
- This option allows PGM-2
output to be utilized as an armed status indicator for
partition two.
Value 00 – 99 Default: 99 (Disabled
)
NOTE
: 09-99 Disables this Output
59B - PGM Output Options
Requires depressing the number
that corresponds to the option that you wish to enable and the
number will be displayed on the LCD. Depressing a number
that previously was displayed will remove the number from the
LCD and disable the option.
OPTION
1 = PGM-1 on Two Wire Smoke Loop
2 = PGM-2 on Two Wire Smoke Loop
3 = PGM-1 on Keypad Fire
4 = PGM-2 on Keypad Fire
5 = PGM-1 on Keypad Panic
6 = PGM-2 on Keypad Panic
7 = PGM-1 on Keypad Emergency
8 = PGM-2 on keypad Emergency
1 - PGM-1 on Two Wire Smokes
- This option allows
PGM-1 to energize when the two wire smoke loop detects
an activation . This output will stay active for the period of
time programmed in memory 58B or when a users PIN is
entered.
2 - PGM-2 on Two Wire Smokes
- This option allows
PGM-2 to energize when the two wire smoke loop detects
an alarm activation . This output will stay active for the
period of time programmed in memory location 58C or
when a users PIN is entered.