
3440-0241 Rev G
10
on the Buss for the amount of time programmed in memory
location 58A or until a valid PIN is entered in the keypad
.
Default: NO
3 - Digital first & Radio second
With this option selected
the digital signal will be transmitted first and if it is
successful, the radio signal will not be sent.
Default: NO
4 - G-FM3 Installed
With this option selected the panel will
recognize the G-FM3 (Fire Module) installed and will
indicate a bus fault should the G-FM3 fail or be removed
from the system
. Default: NO
5 - 50 Hz or 60 Hz
This option is very important to be set
correctly to insure proper operation of the time clock. The
default is set for US operation (60Hz). To set the system
for 50Hz, the number 5 should be showing on the LCD.
Default: 60 Hz
6 - Telco Fault Monitoring Enable
With this option
selected, the keypad will give a visual indication of a
telephone trouble (TLM) and emit a pulsing audible tone
from keypad.
Default: NO
7 - System Test to be Reported on Telco
With this option
selected the panel will automatically transmit the signal to
the central station on the telco line.
Default: YES
8 - Partition System
With this option selected the panel
can be used as two separate systems. The first half of the
zones will automatically become partition number 1 and
the second half of the zones will become partition number
2. PIN's one through eight automatically become assigned
to partition number one and PIN's nine through sixteen will
become assigned to partition number two. Partition
number one will always report its information to Receiver
number one including open and close signals and partition
number two will always report its information to receiver
number two including open and close signals. The house
keeping signals (AC fail, low batt., etc.) report to receiver
one. (See memory location 48 through 53.)
Default: NO
76 A System Features
(Multiple Entries) Requires depressing
the number that corresponds to the option that you wish to
enable and will be displayed on the LCD. Depressing a number
that previously was displayed will remove the number from the
LCD and disable the option.
OPTIONS
1 = Keypad Panic Enabled
2 = Keypad Panic Audible
3 = Keypad Fire Enabled
4 = Keypad Fire Audible
5 = Keypad Emergency Enabled
6 = Keypad Emergency Audible
7 = Key switch or Tamper Inputs
8 = AC fail Audible on Keypad
1 - Keypad Panic Enabled
With this option selected the
keypad panic function is enabled ("AWAY" and "3"). You
may have this function set for silent or audible or both.
Default: NO
2 - Keypad Panic Audible
with this option enabled, the
keypad panic will be audible.
Default: NO
silent only = report code (see memory location 71A).
bell only = no report code + panic audible (see below)
report+bell = report code(see memory location 71A)+
Panic audible (see below)
3 - Keypad Fire Enabled
with this option selected the
keypad fire function is enabled ("STAY" and "6"). You may
have this function set for silent or audible or both.
Default: NO
4 - Keypad Fire Audible
with this option enabled, the
keypad fire will be audible
. Default: NO
silent only = report code (see memory location 70C).
bell only = no report code + fire audible (see below)
report+bell = report code(see memory location 70C)+
Fire audible (see below)
5 - Keypad Emergency Enable
with this option selected
the keypad emergency function is enabled ("INSTANT"
and "9".). You may have this function set for silent or
audible or both
. Default: NO
6 - Keypad Emergency Audible
with this option enabled,
the keypad emergency will be audible
. Default: NO
silent only = report code (see memory location 71).
bell only = no report code + emer. audible (see below)
report+bell = report code(see memory location 71)+
emergency audible (see below)
7 - Key switch or Tamper Inputs
When the key switch
option is selected terminals 7 and 10 will support any
momentary or latching arming station. The number 7
should be displayed on the LCD to select the key switch
input. The number 7 should not be displayed if you need to
use as a tamper switch. A report code must be
programmed in memory location 69C when selected for
tamper switch input, This tamper input is silent only.
Default: Tamper Switch
8 - AC Fail Audible on Keypad
Should there be a loss of
AC power, this option will enable an audible tone to emit
from all keypads, together with AC trouble display on the
LCD. Only AC trouble will display on the LCD if this option
is not selected.
Default: NO
76 B Monitor Mode Features
(Multiple Entries)
Requires depressing the number that corresponds to the option
that you wish to enable and the number will be displayed on the
LCD. Depressing a number that previously was displayed will
remove the number from the LCD and disable the option.
(See next page).
Comentarios a estos manuales