3440-0241 Rev G
1
HOW TO ENTER PROGRAM MODE
The Installers PIN is required to access the Installers
program. The
Installers PIN is Preset from the factory as
[9999]
and may be changed in Location 78. Care must be
taken when changing Installers PIN.
To enter Program Mode:
Depress
[Installer PIN] + [
] + [7]
. The LCD should
now display
You are now in program mode.
MOVING WITHIN INSTALLERS PROGRAM MODE
Once within the Installers program mode, movement is
achieved by selecting specific Memory Locations and
going to those locations. Each Memory Location is
identified with a two-digit number. Entering that
number at the prompt will advance you to that specific
location and display any memory within that field.
To access a Sub-Location (example, 56B
), enter the
two digit location number and press the [
] button until
the appropriate sub-location is displayed. To move
back to a previous Sub Location within that memory
location, press [STAY]. To move from one location to
another press [#] then enter new location number.
Once within the field, changes can be made by either:
A)
Entering the appropriate two digit number or,
Memory Location
Two Digits number
B)
By entering the number that corresponds to the
option that you wish to enable .
Memory Location
Option Number
Example: If you depress 1-2-6 , the LCD will indicate
those three options have been enabled. Depressing a
number that previously was displayed will remove the
number from the LCD and disable the option
When the desired changes are made, simply depress
the [
] button to lock the information in the EE prom
and advance to the next memory field.
To exit a specific Program Location, press the [#]
button. This will exit you back to the (PRG.) prompt.
When all changes have been completed, depress the
[#] button twice to exit out of the Installer Program
mode.
Memory Location 00 - 46
CUSTOM ZONE PROGRAMMING
All of the GENESYS 824 zones can be custom
programmed to perform any number of specific
functions. For each zone you will be making several
decisions about the functions it will perform. The
choices are as follows.
ZONE TYPE
*Check Programming Sheet for Defaults.
The first two-digit entry defines the
Zone Type
as well
as the
Loop Type
.
Memory Location
(00 : Zone 1 )
Zone Type
Loop Type
(Default:2)
(Default:2)
Zone type is the first digit entry. The zone types
and the value to enter are:
0 - ENTRY - EXIT 1
1 - ENTRY - EXIT 2
2 - PERIMETER INST
3 - INTERIOR 1
4 - INTERIOR 2
5 - INTERIOR 3
6 - 24 HOUR
7 - FIRE 24 HOUR
8 - DAY CIRCUIT
0 - ENTRY - EXIT 1
used for an Entry/Exit zone where
a delay is required to Enter or Exit the premises.
1 - ENTRY - EXIT 2
may be used on entry exit zones
requiring longer periods of time, such as garage doors,
gates, outdoor detectors, etc. This zone type may also
be used in a partitioned system where a separate entry
or exit time is required for each partition.
2 - PERIMETER INSTANT
used for devices that
should create an instant alarm when the system is
armed in any mode.
3-4-5 - INTERIOR 1 - 2 - 3
used for devices such as
PIR, Ultrasonics, Mats, etc. that are used inside the
premises.
6 - 24 HOUR
is used for devices that will activate an
alarm condition whether the panel is armed or
disarmed.