Page 78
Entry/Exit Chime
When Entry/Exit Chime is set to Yes, the console(s) will beep once when a door on an entry/exit zone is opened, even if the alarm
system is off. This lets you know when someone enters and leaves.
The default setting for Entry/Exit Chime is Yes.
Perimeter Chime
When Perimeter Chime is set to Yes, the console(s) will beep once when a window or any other perimeter zone is opened, even if
the alarm system is off.
The default setting for Perimeter Chime is Yes.
Enable Quick Arm
The Quick Arm feature allows the security system to be armed by pressing the desired mode key twice instead of having to enter
your code.
The default setting for Enable Quick Arm is No.
Enable Auto Bypass
The Auto-Bypass feature allows the system to automatically bypass an open zone when the system is armed, rather than setting off
the alarm. In some applications, it may be preferable to allow arming only if all zones are secure (READY).
With Auto-Bypass set to “No”, all zones to be armed must be secure when the system is armed. Otherwise, the console will beep
three times and display "ZONE NOT RDY". If the system is armed and a zone is open when the Exit Delay expires, the alarm
will sound.
The default for Enable Auto Bypass is No.
All On For Alarm
This option will instruct OmniPro II to execute an X-10 All On command in the event that any type of alarm occurs.
Beep On Trouble
If the OmniPro II detects any troubles with itself or one of the zones connected to it, it will display a message on the screen and
beep the console twice per second, continuously (i.e. beep beep...beep beep...). You can silence this sound by pressing the ' * '
key. However, if the trouble occurs again, the beeper will start beeping again.
If you do not wish to hear the beeping sound when a trouble occurs, set Beep On Trouble to No.
The default setting for Beep On Trouble is Yes.