Page 24
Each lighting scene can also be set or easily changed using the pushbuttons on the LEVITON UPB™ 6-Button Room Controller,
as follows:
Step
Operation
1
Press the desired pushbutton on the LEVITON UPB™ 6-Button Room Controller to activate the current scene (preset
lighting level) in each of the HLC devices.
2
Use the local rocker switch on each UPB™ Wall Switch Dimmer(s) to set the desired lighting level(s) or issue
commands from the OmniPro II controller.
3
Press the pushbutton on the LEVITON UPB™ 6-Button Room Controller five (5) times quickly.
4
Each UPB™ Wall Switch Dimmer will flash its lighting load one time to indicate that the new level has been
configured.
Controlling Individual Lighting Loads in an HLC Room or UPB Units
To control individual lighting loads in a room, use the down arrow key to scroll through the list of units. When the unit is
displayed, press the ' # ' key. For HLC/UPB lighting loads, the console will display:
LR Sconce
0=OFF 1=ON 2=DIM 3=BRT
LR Sconce
4=LVL 6=LED 9=TIM #=STA
Press 0 (OFF) to turn the selected lighting load off .
Press 1 (ON) to turn the selected lighting load on.
Press 2 (DIM) to dim the selected unit (1-9 steps, each step is 10% from its current level).
Press 3 (BRT) to brighten the selected unit (1-9 steps, each step is 10% from its current level).
Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%).
Press 6 (LED) to turn on or off the LED behind the specified button on a general purpose 8-Button or 6-Button Keypad.
Specify 1-8 to control the LED behind buttons 1-8 respectively, and then select 0 (OFF) or 1 (ON).
Press 9 (TIM) to time the selected unit (On, Off, Dim, Brighten).
Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18 hours.
Press # (STA) to see the exact status of a UPB device. When the ' # ' key is pressed, OmniPro II sends a “Status
Request” message to the selected device for its current state. The exact state is then displayed.
LR Sconce
STATUS 67%
Note: When a UPB signal is received over the powerline, OmniPro II will automatically update the status of the device.
Controlling Vizia RF Z-Wave
It is imperative that each unit be named. If a unit is not named, it will not show up in the list of rooms and loads that are able to
be controlled. The only exception is for additional push button controllers. If you have assigned a Node ID to a Unit, but do not
name it, the OmniPro II will interpret that as a push button controller, so Z-Wave messages from that push button controller will
not be ignored.
Controlling a Room of Vizia RF Z-Wave Lighting
Living Room
0=OFF 1=ON 2-5=A-D
Living Room
6=SET #=STA