C-0636-030-060
10.4
Access the Handier as shown in Figure 8.
a.
b.
C.
d.
e.
f.
Starting at
OmegaWand
2.6, scan the
ADVANCE bar code until 636 Keypad
##.##
appears. Scan ENTER.
636M: New
File
appears, scan ENTER.
When 636M
:
appears, enter
a
file name.
Scan ENTER to access Zone
1
Display.
Scan ENTER or ADVANCE and the Zone 1
custom text display appears
(>
).
Enter up to 15 characters of Custom text for
Zone
1,
centerthe text in the display, and stroke
ENTER.
g.
h.
The next Zone
#
Display
will appear. Follow
steps e
-
g until custom text has been assigned
to each Zone and to the
Custom
Text
display.
Save your program if necessary. The same
program must be loaded into each
D636A
on
the same account.
10.5
On the
D636A,
press keys 4 and 6 simultaneously
and hold while switching
Power
on the
Programming Dip Switch to the ON position.
D636A
Display:
PROGRAMMING
I
Release the keys.
10.6
Load the 638 Keypad program from the
D5100
to
the
D636A
Command Center by stroking
LOAD
PANEL
on the
D5100.
D636A
Display:
L
NOTE:
This display also appears when Copying
the program from the
D636A
to the D5100 Bar
Code Programmer.
10.7
Disconnect the
D5100
Prgrammer from the
D636A
and turn the
Data
switches to the ON position.
10.8
Remove the Disable Jumper from the Control/
Communicator.
10.9
11.
Test your
D636A
Command Center to confirm the
Custom text programming.
Programming the D4112 and
D6112
_
The device model programming
(6112=4.2
D
I Model
and
D4112=
1 Account,
Device
1
Type)
for the
D636A
is programmed as a 3, the same as for a 0630 Command
Center.
ADVANCE
636
Keypad
UY
ADVANCE
Other
Handheld
ENTER
636
New
Flh
ADVANCE
Other
636
Files
1
ENTER
4
636M:
Enter
New
File
Name
ADVANCE ENTER
Zone
1
Display
ADVANCE ENTER
Enter the Custom Text for
,
each
zone
ADVANCE ENTER
Zone 2
Display
ADVANCE ENTER
l
ADVANCE ENTER
Zone
16 Display
ADVANCE ENTER
,
ADVANCE ENTER
Custom Text
ADVANCE ENTER
i;]
ADVANCE/ENTER
Enter the Custom Text
for
the Idle display.
Figure 8:
D636A
Programming
12. System Trouble Report Codes
(COMMAND 42 and COMMAND
40)_
Typically, when a system trouble occurs, the trouble
buzzer of the command center sounds. When the
subscriber reports this condition to the Central Station
operator, the subscriber may be instructed to enter a
COMMAND 42 at the
D636A
(See 5.10
Cmd42,
in the
D6112 Program Entry Guide
#74-04367-000,
and Sys
Test/Reset,
Cmd42DiagRpt,
in the
D4
112 Installation
and Programming Manual
#74-05365-000).
If
pulsed format
is transmitted, only the trouble report
code is sent to the central station. If there are no system
troubles present when COMMAND 42 is entered, a
restoral
report is transmitted. If the communicator
transmits in
BFSK format,
a trouble report code and
STATUS REPORTis sent to the central station. If there
are no system troubles, a
restoral
report and STATUS
REPORTis transmitted. If the
Modem II
format is used
by the communicator, a trouble report code and
DIAG
REPORTis sent to the central station. If there are no
system troubles, a DIAG REPORTis transmitted.
Keying COMMAND 40 or 42 at the
D636A
Command
Center displays a trouble report. If applicable, a second
trouble
report
can
be displayed by keying in the command
again. Maximum number of trouble reports that can be
held in the Command Centers trouble memory is two.
7
74-05475-000-c
4/90
D636A Operation/installation Instructions
Page
6
Q 1989-1990 Radionics, Inc.
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10

Comentarios a estos manuales

Sin comentarios