Myalarm D420 Especificaciones Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 10
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
C-0636-030-050
9.3 Mount the Enclosure Base
-
Place the enclosure
base on the wall in the desired location. Use a
centerpunchorapenciltomarkthelocationsofthe
mounting holes. (The enclosure base can be
mounted to a single-gang wall box if desired. Two
mounting screw holes on the base are positioned
for standard single-gang compatibility.) Secure
the enclosure base to the wall or gang box.
9.4
Adjust the Display Contrast
-
Adjust the
Potentiometer (see Figure 2) for optimum display
contrast.
custom text programming should be completed
before replacing the front cover. Custom text
programming can be found in Section 10.
9.6
Replace the Front Cover
-
Align the top two tabs
of the enclosure cover with the top two tab slots in
the enclosure base. Slide the top of the cover into
the base. Gently push the bottom of the cover
down on the base until it snaps into place.
9.7
Adjust the Keys
-
Push each key on the keypad
towards the top of the enclosure to ensure proper
mating with the openings in the top cover.
9.5
Program the
D636A
Command Center
-
Since
the programming jack is located inside the
D636A,
10. Custom Text Programming for the D636
The
D636A
custom text for each zone is programmed
There are two types of Custom Text that can be
using the D5100 Programmer loaded with the
D636A
programmed, Custom Text for each zone, and Custom
Keypad Handler (74-05569-000). (When using the
Text for the Idle display. Each Custom Text display can
D5100 Programmer, refer to the
D5100
Operation and
be up to 15 characters long. Standard text (which is not
Installation manual
#74-02521-000.)
programmable) appears on the first line of the
D636A
Display and Custom Text appears on the second line.
Below is an example of both types of text.
Idle Display
Zone Display
10.1
10.2
10.3
Disable the Control/Communicator by attaching a
Jumper from the Reset Pin to common until
programming is completed. This
is
done to prevent
the Control/Communicator from reporting to the
Central Station while the
D636A
is being
programmed.
D636 Display:
Display alternates between idle display. If the
display is not on, remove the jumper and try the
procedure again.
NOTE:
While it is disabled, verify the Control/
Communicator is still supplying power to the
D636A.
Switch
Power
and both
Data
switches on the
D636A
Programming Dip Switch (see Figure
7),
to
the OFF position.
Connect the D5100 to the
D636A
Programmer
Connection (see Figure 3 and 7) using the
D5106
Programmer Interface Cord or the
D5103A
Programmer Cord.
ZONE JUMPERS
PROGRAMMING
DIP SWITCH
POWER
DATA
DATA
PROGRAMMER
CONNECTION
L
Figure 7: PROGRAMMING DIP SWITCH
74-05475ODD-C
4/90
D636A Operation/Installation Instructions
Page 5
Q
1989-1990 Radionics, Inc.
Vista de pagina 6
1 2 3 4 5 6 7 8 9 10

Comentarios a estos manuales

Sin comentarios